To find a short circuit on a phone logic board, all you need is a digital multimeter in buzzer mode and a few measurements at the battery connector. The readings in one direction and then the other tell a half short from a full short. The method works on iPhones and Android phones alike.

Video (in French): Diagnosing a logic board with freeze spray?

Half short and full short

The half short: a phone that turns on but drains

The phone turns on and seems to work normally, but the battery drains very fast. In that case there is dry solder on the logic board, or an SMD (surface-mount device), a capacitor for example, is faulty. It has to be removed or, ideally, replaced.

The full short: a phone that will not turn on

The phone is dead. One or more major electronic components are faulty, and the board needs a careful look under the microscope.

Measuring shorts with a multimeter

Spotting a half short

  1. Keep the digital multimeter in buzzer mode.
  2. Measure the battery connector in the forward direction (red probe on positive, black probe on negative). If the display shows 1, the logic board is fine: there is no short.
  3. If the displayed value is 25, there is a half short.
  4. Next, measure in the reverse direction (red probe on negative, black probe on positive). A value between 350 and 650 means there is no short.
  5. If the reverse value is 350, there is a half short.
  6. If the value is the same in both directions, there is also a half short.

Recognizing a full short

  1. A beep in both directions (forward and reverse) signals a full short.
  2. Another test: connect positive (+) and negative (-) of the battery connector to a DC power supply. If the current reading climbs and the phone does not turn on, the board has a full short.

Fixing a half short

Take the phone apart, clean the logic board thoroughly with isopropyl alcohol, then apply heat to the whole board with the hot air station. Put the phone back together and check whether the problem is gone.

In most cases it is. If the half short stays, look for small SMD capacitors near the battery connector and remove the faulty ones.

Finding and replacing the shorted component on a full short

Connect positive (+) and negative (-) of the battery connector to a DC power supply. The amp reading climbs while the phone does not turn on: that is the sign of a full short.

The faulty component heats up. You can feel the heat with a finger, or spot the flux residue that does not form on the shorted SMD. That component has to be replaced.

This is the most common procedure, and there are of course isolated cases. For the diagnostic part, a digital multimeter is enough.

Watch the video on YouTube

Video thumbnail showing a freeze spray short diagnosis on a phone logic board

Going further in diagnostics

To learn to replace the faulty component under the microscope, the Level 3 micro-soldering program is built for it. If you want a shorter format, the one-week diagnostics intensive focuses on board-level diagnosis. You can also browse all programs or join the community to ask other techs.

Find more content on our YouTube channel.